Roseville CA Plumbing, Heating, and Air Conditioning Service

Roseville Drain Cleaning and Clearing Expert

Roseville Service Area & Reviews

Crystal Blue Plumbing, Heating & Air provides heater and air conditioning repair, service, installation and services in Roseville CA and surrounding areas. Check out what some of our customers are saying about Crystal Blue Plumbing, Heating & Air Plumbing, Heating and Air Conditioning services.

Plumbing, Rooter, Heating & Air Conditioning Services in Roseville, CA

The Crystal Blue Heating & Air team Provides top-quality 

Award Winning Service with over 35 years of Experience!

Complete 24/7 Emergency Services:

  • Air conditioner not working
  • Sewer line stoppages
  • No heat
  • Kitchen and bathroom drain clogs
  • Leaking & broken water heaters
  • Overflowing toilets
  • Pipe leaks

Blue Oaks, Quail Glenn, Sun City Roseville, Dell Webb, Junction West, Highland Reserve, Foothill Junction, East Roseville Parkway, Creekside, Stanford

Local Reviews
for Roseville, CA

Rated 5.0 out of 5 stars based on 56 customer reviews

Map of Roseville, CA

Great Service





Map of Roseville, CA

Verry Happy with the Service!!! Definately will recommend to my friends!





Map of Roseville, CA

AC Tune Up




Mike tuned up our AC for the summer ahead. It's already working more efficiently. He walked us through the process and got our system back into shape. Would recommend.


Map of Roseville, CA

Tom was very pleasant and helpful





Map of Roseville, CA

MIchael is a GREAT employee. Please reward his hard work




Michael is very personable and friendly, even after working from 7am to 9pm


Map of Roseville, CA

prompt and professional




showed up ahead of schedule, diagnosed everything quickly and got it all working great!


Map of Roseville, CA

Great service





Map of Roseville, CA

great service




Michael, was neat and made sure all our questions were answered. When he found a problem he took me to the area and made sure I saw what the problem was. When he was testing the air conditioner it would have been nice to let us know it had to run for 20 minutes, we almost froze thinking he forgot to turn it off.


Map of Roseville, CA

attic




I see that Mike is a awsum man and takes his time to get the bid right He can do!! JUSt about anything as he puts his ma=ind to it. I fee that he can be trusted in my home and that in it self is worth that weight in gold for all that he does.


Map of Roseville, CA

SEAN




A great wonderful young man! Hope he nevers changes. He was all knowledge as he answered all my questions as I ask when he was in operation of his job here. He understood that I understood! what he had to do here with my hot water tank. SO pleased to have him in my home!!


Tom D.

Tom D.

Technician will attempt to run quarter inch flexible cable through inch and a half and 2 in PVC drain lines from. No warranties on drain clearing. Drain clearing successful line is clear technician cleared line with quarter-inch cable machine through 2 in PVC line to pump.AUTH ID 115722

Near Kingsgate Dr, Roseville, CA 95746
michael E.

michael E.

Roseville California heating AC service AC maintenance AC diagnostic AC maintenance Lennox hvac split system. Inspection of electrical (good) no burning or overheating of wire connections. Contactor good contact points slight pitting / burning not affecting operation at this time. Amp draws on outdoor fan motor and compressor good 1.2 and 15.6 Check refrigerant charge found system slightly under charged could be caused from possible leak in the system or never accurately charge from install. Performed simple water wash on condenser coil no charge part of ac maintenance. Tightened all wire connections and screws disconnect quarter turn loose on supply voltage side. Charged system to manufacture specifications. recommend checking refrigerant charge next summer if low recommend leak search to determine cause of leak.

Near Goodstone Way, Roseville, CA 95747
michael E.

michael E.

Roseville California heating AC service AC maintenance AC diagnostic Rheem gas package unit roof AC not cooling no cold air out of vents. diagnostic findings system has bad capacitor not starting compressor which cycles refrigerant which creates the cooling for the system. Replaced capacitor checked operation system unit turns on and is cooling. Capacitor that failed was not original capacitor and when it was replaced it was replaced with a used part and did not match microfarad specs needed to properly run motor and compressor. installed two separate capacitors in place of one matched capacitors to motor and compressor ratings. Installed capacitors against back plate with support bracket so to not fall over and electrically short out unit.

Near Meadowlark Way, Roseville, CA 95661
Sean D.

Sean D.

Expansion tank has failed and bladder is breaking up customer is seeing black partiicals from faucets will replace tank and flush water heater to clean out any buildup performed plumbing inspection all good only found loose closet bolt reinstalled float to ceiling

Near Langtree Dr, Roseville, CA 95747
Sean D.

Sean D.

Expansion tank has failed and bladder is breaking up customer is seeing black partiicals from faucets will replace tank and flush water heater to clean out any buildup performed plumbing inspection all good only found loose closet bolt reinstalled float to ceiling

Near Langtree Dr, Roseville, CA 95747
Rayne V.

Rayne V.

Technician could not find leak in front yard or back yard irrigation control valves. Technician adjusted float on ornamental pond pump to resolve issue.

Near Arlington Ct, Roseville, CA 95747
michael E.

michael E.

Roseville California heating AC service AC maintenance AC diagnostic customers complaint blower intermittently coming on. inspected capacitor found reading below microfarad rating. needs capacitor replacement bad cap is cause of blower motor intermittently capacitor not starting motor all the time Replaced capacitor tested system found unit operating normally no other problems at this time

Near Loretto Dr, Roseville, CA 95661
Rayne V.

Rayne V.

Replacing the ice maker line and angle stop Cabinets have a line already So no need to drill behind cabanit

Near Astill Way, Roseville, CA 95678
Jaime C.

Jaime C.

Had water damage while on vacation they only want an inspection to make sure there's nothing else had water damage while on vacation they only want an inspection to make sure there's nothing else to do leaking Check faucets and toilets in the bathrooms underneath kitchen Fossett there is a line that feeds the fridge that is leaking water Line needs to be replaced and also angle stop has to be replaced because it's leaking as well

Near Astill Way, Roseville, CA 95678
michael E.

michael E.

Installation of quiet cool smart attic fan model AFG smt-3.0 Seal two 6" ducts that were abandoned in attic

Near Sidesaddle Way, Roseville, CA 95661
michael E.

michael E.

Roseville California heating AC service AC maintenance AC diagnostic Goodman split system AC breaker keeps tripping Diagnostic findings direct short from compressor run windings Repair options 1. replace compressor recharge system with R22 refrigerant with proper procedures vac, pressure test, replace filter dryer. 2. Replace compressor and charge system with new refrigerant R407c a compatible match with old R22 refrigerant. this will require changing TXV and valve stems. proper procedures done vac, pressure test, replace filter dryer. 3. Replaced ac system with R410a refrigerant system this will require changing outdoor unit and indoor evap coil. Maybe possible to change TXV on evep coil to R410a refrigerant TXV. need to check specifications on coil due to pressure rating on coil is rated for higher pressure refrigerant just does not specify that it can be use R410a refrigerant.

Near Red Squirrel St, Roseville, CA 95747
michael E.

michael E.

Roseville California heating AC service AC maintenance AC diagnostic Goodman split system AC breaker keeps tripping Diagnostic findings direct short from compressor run windings Repair options 1. replace compressor recharge system with R22 refrigerant with proper procedures vac, pressure test, replace filter dryer. 2. Replace compressor and charge system with new refrigerant R407c a compatible match with old R22 refrigerant. this will require changing TXV and valve stems. proper procedures done vac, pressure test, replace filter dryer. 3. Replaced ac system with R410a refrigerant system this will require changing outdoor unit and indoor evap coil. Maybe possible to change TXV on evep coil to R410a refrigerant TXV. need to check specifications on coil due to pressure rating on coil is rated for higher pressure refrigerant just does not specify that it can be use R410a refrigerant.

Near Red Squirrel St, Roseville, CA 95747
michael E.

michael E.

Roseville California heating AC service AC maintenance AC diagnostic Goodman split system AC breaker keeps tripping Diagnostic findings direct short from compressor run windings Repair options 1. replace compressor recharge system with R22 refrigerant with proper procedures vac, pressure test, replace filter dryer. 2. Replace compressor and charge system with new refrigerant R407c a compatible match with old R22 refrigerant. this will require changing TXV and valve stems. proper procedures done vac, pressure test, replace filter dryer. 3. Replaced ac system with R410a refrigerant system this will require changing outdoor unit and indoor evap coil. Maybe possible to change TXV on evep coil to R410a refrigerant TXV. need to check specifications on coil due to pressure rating on coil is rated for higher pressure refrigerant just does not specify that it can be use R410a refrigerant.

Near Red Squirrel St, Roseville, CA 95747
michael E.

michael E.

Roseville California heating AC service AC maintenance AC diagnostic commercial AC maintenance unit 701 suite Visual inspection air filters plugged removed to replace found evap coil dirty plug restricting airflow. electrical connections service disconnect tight contact. incoming line voltage to contactor tight. compressor connections on contactor burnt overheated wire adding stress to compressor. recommend replacing terminal connection. Capacitor 40/5 Reads 39.5/5.1 compressor and outdoor fan capacitor good. Blower capacitor 15 reads 14 bad out of manufactures tolerance. recommend replacing blower capacitor Cleaned electronic control board removed dust. perform simple brush off on evap coil for customer, water washed condenser coil, tightened all wire connections, remove wasp nest out of service disconnect. Tested amp draws good. Refrigerant pressures good AC maintenance unit 702 suite water wash condenser coil. change air filter's in the process of changing air

Near Junction Blvd, Roseville, CA 95678
michael E.

michael E.

Roseville California heating AC service AC diagnostic AC maintenance trane split system AC condenser. Visual inspection capacitor leaking oil, Contactor contact points have pitting and burning. Amp draws compressor 15.4 actual 11.74 condenser fan motor 1.4 actual 1.3 (good) Capacitor test bad 45/5 reads 42.2/5.1 just out of manufactures tolerance recommend replacement due to capacitor leaking oil and being out of manufactures tolerance. If the capacitor fails completely will cause stress on compressor possibly causing premature failure. While connecting gauges to system smell of bubble gum typically indicates sealant has been added to system. Refrigerant pressures so system is low on charge super heat 43.5 subcooling 4.2 low side pressure 99.9 Hi side pressure 334.4 / superheat should be around 15 Sub cooling should be around 10 low side pressure should be around 120 high side pressure should be around 344. Recommend charging system to manufactures specifications for better

Near Ben Ezra Ave, Roseville, CA 95678
michael E.

michael E.

Roseville California heating AC service AC diagnostic lennox split system Diagnostic found system with high side pressure little high caused by dirty condenser coil and system slightly low on refrigerant causing temperatures inside to not cool efficiently or as well as it could

Near Sierra Blvd, Roseville, CA 95678
Sean D.

Sean D.

Found water leak above water heater in ceiling corroded teen caused by electrolysis pipe is we've been allowed water to come down the supply feed off water heater accessibility difficult will have to move water flexes flu pipe cover top of water heater and cut open the ceiling to expose area to make repair three-quarter copper

Near Sierra Blvd, Roseville, CA 95678
Sean D.

Sean D.

Found water leak above water heater in ceiling corroded teen caused by electrolysis pipe is we've been allowed water to come down the supply feed off water heater accessibility difficult will have to move water flexes flu pipe cover top of water heater and cut open the ceiling to expose area to make repair three-quarter copper

Near Sierra Blvd, Roseville, CA 95678
michael E.

michael E.

Reconfigure drain lines for proper slope / drainage so unit can drain properly and prevent possible water damage

Near Farridge Dr, Roseville, CA 95678
Sean D.

Sean D.

Blockage in supply to hot side kitchen faucet cleared blockage hot water is restored to kitchen Fossett cause of blockage is unknown black substance kind of like a rubber. Customer purchased service club membership will perform water heater flush clean top of water heater and control valve ensure that there is no obstructions to the intake air will also investigate all under all vanity sinks for any types of leaks or defects in plumbing material

Near Sierra Blvd, Roseville, CA 95678
Sean D.

Sean D.

Blockage in supply to hot side kitchen faucet cleared blockage hot water is restored to kitchen Fossett cause of blockage is unknown black substance kind of like a rubber. Customer purchased service club membership will perform water heater flush clean top of water heater and control valve ensure that there is no obstructions to the intake air will also investigate all under all vanity sinks for any types of leaks or defects in plumbing material

Near Sierra Blvd, Roseville, CA 95678
Sean D.

Sean D.

Blockage in supply to hot side kitchen faucet cleared blockage hot water is restored to kitchen Fossett cause of blockage is unknown black substance kind of like a rubber. Customer purchased service club membership will perform water heater flush clean top of water heater and control valve ensure that there is no obstructions to the intake air will also investigate all under all vanity sinks for any types of leaks or defects in plumbing material

Near Sierra Blvd, Roseville, CA 95678
Sean D.

Sean D.

Blockage in supply to hot side kitchen faucet cleared blockage hot water is restored to kitchen Fossett cause of blockage is unknown black substance kind of like a rubber. Customer purchased service club membership will perform water heater flush clean top of water heater and control valve ensure that there is no obstructions to the intake air will also investigate all under all vanity sinks for any types of leaks or defects in plumbing material

Near Sierra Blvd, Roseville, CA 95678
michael E.

michael E.

Roseville California heating AC Service AC maintenance York split system AC condenser forced air furnace Visual inspection Ductwork intact no disconnected or damaged ductwork System little water in secondary evap coil pan. Cause is due to unit has settled causing drain lines to slope towards unit instead of away. causing system to hold excess water and flow out of secondary drain line. Visual inspection of electrical outside no burning or overeating wires in disconnect no burning overheating of wire connections in AC unit. Wire connections loose in disconnect tightened as part of AC maintenance. incoming line voltage on contactor loose tightened is part of AC maintenance. Contactor slight pitting and burning on contact points not affecting function at this time. Capacitor 35 / 5 reads 36 / 5.2 capacitor good Compressor Mega ohm test good Amp draws compressor 21.8 actual 15.45 outdoor fan 1.6 actual 1.03 amp draws good Refrigerant pressures good water wash condenser coil as part of

Near Farridge Dr, Roseville, CA 95678
michael E.

michael E.

Roseville California heating ac service AC maintenance York split system AC condenser gas forced-air furnace Visual inspection of unit unit operationable turns on. Inspection of service disconnect incoming line voltage aluminum wire about 3/4 turns loose. tighten is part of AC maintenance other wires and disconnect tight. No burning overheating connections. Contactor incoming line voltage wires about half turn loose. tightened is part of AC maintenance contact points on contactor little burning little arcing. operationable at this time. capacitor 60/5 reads 59 / 4.8 capacitor test good Compressor winding test .9 / 1.8 / 2.3 compressor winding test within specs compressor Mega ohm winding test to ground testing caution. compressor shows where compressor can fail at any time. connection refrigerant gauges refrigerant smell is a little burnt. Refrigerant pressures low side 77.5 high side 183.9 superheat 11 subcooling 11 outdoor temperature 82 indoor temperature 75 with current temper

Near Langtree Dr, Roseville, CA 95747